Battery Thermal Abuse Test Chamber reproduces the heating profiles required by GB 31241 and UN38.3 thermal abuse tests, up to 150°C with programmable ramp rates.
Key features: programmable temperature profiles, explosion-venting structure, observation window, data export for certification reports.
Specifications
Item Specification Model DY-6009C Chamber · inner dimensions 500 (W) × 600 (D) × 500 (H) mm Chamber · outer dimensions 870 (W) × 720 (D) × 1370 (H) mm (nominal) Chamber · inner material 430# mirror-finish stainless steel, 1.0 mm Chamber · outer material 1.0 mm cold-rolled steel, powder coated (wrinkle grey-white) Chamber · insulation High-temperature rock wool Chamber · sealing High-temperature foamed silicone gasket Chamber · shelves Two adjustable levels (first at 100 mm from bottom), two wire shelves supplied Chamber · viewing window W200 × H250 mm on the door Chamber · test port One ?50 mm port on the right side Chamber · door Single door, right-to-left opening; control panel mounted above the chamber Chamber · mobility Swivel castors plus adjustable levelling feet Temperature · controller 580 touchscreen, constant-value or programmable operation, auto-tuning, PV/SV displayed together Temperature · range Ambient +20 to 200 °C, adjustable Temperature · heating rate 5 ± 2.0 °C/min, program-controlled Temperature · control accuracy ±0.5 °C Temperature · display resolution 0.1 °C Temperature · test setpoint 130 ± 2.0 °C (no-load test) Temperature · deviation ±2.0 °C at 130 °C / 150 °C (no-load test) Temperature · sensor PT100, high-temperature type Temperature · control output 3–32 V signal; SSR (solid-state relay) switching Temperature · heating element High-temperature type Temperature · timing Built-in timer, starts counting when temperature is reached; stops heating and alarms on completion Temperature · data port RS232 PC connection; temperature curve viewable on the touchscreen Air circulation · airflow Internal hot-air circulation, outlet on left, return on right Air circulation · motor Long-shaft high-temperature motor, 370 W / 220 V Air circulation · fan Multi-blade turbo fan, 9 in Air circulation · ports One inlet on the right side, one exhaust port on the left Protection · over-temperature Heating is cut automatically when the over-temperature limiter setpoint is exceeded Protection · electrical Earth protection, fast fuse, overload protection, circuit breaker Safety · pressure relief W200 × H200 mm explosion-venting port at the rear, releases the pressure wave if a cell vents Safety · door Explosion-proof chains at the four door corners prevent the door from flying open Applicable standards
Standard Scope International reference GB 31241-2014 Lithium-ion cells and battery packs for portable electronics — safety, incl. thermal abuse IEC 62133-2 GB/T 18287-2013 Lithium-ion battery packs for cellular phones — UN38.3 Transport tests incl. thermal test UN Manual of Tests and Criteria, Part III, 38.3 IEC 62133-2 Secondary lithium cells and batteries — safety requirements — UL 1642 / UL 2054 UL safety of lithium cells / battery packs — Dongguan Dongyang Machinery Co., Ltd. — manufacturer of 200+ reliability testing machines. Contact us for quotation: 13790146684 (WhatsApp/WeChat available).