13-year testing machine manufacturer
Improve quality with cutting-edge technology, testing experts by your sideAltitude Low Pressure Test Chamber for UN38.3 T.1 and T.2
- Date:2026-10-31
- Visits:1127
- Description
- Related products
Altitude (Low Pressure) Test Chamber simulates air transport conditions up to 30000 m for lithium batteries per UN38.3 and GB/T 2423.21 low pressure tests.
Key features: vacuum system with precise pressure control, transparent observation window, safety interlocks, suitable for cells and small equipment.
Specifications
Item Specification Model DY-6004-70D Chamber · inner dimensions 700 (W) × 700 (D) × 700 (H) mm Chamber · outer dimensions 1200 (W) × 1150 (D) × 1780 (H) mm (nominal) Chamber · inner material SUS304 high-temperature industrial stainless plate, 5.0 mm, reinforced against vacuum deformation Chamber · outer material 1.2 mm cold-rolled steel, double-sided baked enamel (beige) Chamber · insulation Fibre rock wool, 100 mm thick Chamber · structure Upper section is the test chamber; lower section houses the control cabinet and vacuum pump Chamber · sealing High-density silicone door gasket Chamber · door Single door, right-to-left opening; control panel at the lower front Chamber · shelves Three levels, three shelf plates supplied Chamber · viewing window 350 × 350 mm on the door Chamber · mobility Swivel castors plus adjustable levelling feet Temperature · controller Digital indicating controller (Taiwan Taisong), single-setpoint, auto-tuning, PV/SV displayed together Temperature · range Ambient +15 to 150 °C, adjustable Temperature · heating Three-surface radiant heating — left wall, right wall and chamber floor Temperature · heating element High-temperature stainless steel heating tube Temperature · sensor Type K thermocouple Temperature · control output 3–32 V, SSR solid-state relay switching Temperature · control accuracy ±0.5 °C Temperature · display resolution 0.1 °C Temperature · deviation ±6 °C (measured without vacuum) Temperature · timer 0–9999 h / min / s; starts when temperature is reached, then stops heating and alarms Vacuum · gauge Panasonic digital vacuum gauge Vacuum · sensor Automatic barometric sensing Vacuum · range 0.0 kPa to ?100.0 kPa (relative) Vacuum · leak rate approx. 1.0 kPa per hour when held Vacuum · control Automatic — pump stops at the upper setpoint and restarts at the lower setpoint to hold the low-pressure state Vacuum · reading convention Gauge reads relative pressure: for an absolute 70.0 kPa, set 101.3 ? 70.0 = ?31.3 kPa Vacuum pump XD-20, 220 V, 0.9 kW; exhaust must be ducted outdoors (by the customer) Protection · over-temperature Independent over-temperature limiter cuts the heater supply Protection · electrical Phase-sequence, earth, overload and circuit-breaker protection Operating environment 5–25 °C, 35–75 %RH Power supply 380 V / 50 Hz, three-phase five-wire Current 23 A Rated power 6.0 kW Applicable standards
Standard Scope International reference UN38.3 Transport test T.1 — altitude simulation (≤ 11.6 kPa, 6 h, 20 ± 5 °C) UN Manual of Tests and Criteria, Part III, 38.3 GB/T 2423.21 Environmental testing — low air pressure test methods IEC 60068-2-13 IEC 60068-2-13 Environmental testing — low air pressure — Dongguan Dongyang Machinery Co., Ltd. — manufacturer of 200+ reliability testing machines. Contact us for quotation: 13790146684 (WhatsApp/WeChat available).