13-year testing machine manufacturer
Improve quality with cutting-edge technology, testing experts by your sideVW-1 Vertical Flame Test Chamber per UL 1581 Section 1080
- Date:2026-10-31
- Visits:1131
- Description
- Related products
Large Vertical Flame Test Chamber performs VW-1 and related vertical burning tests on wires, cables and plastic parts per UL1581 and UL94.
Key features: standardized burner and flame calibration kit, flow meters, chamber observation window, compatible with FT-2 horizontal tests.
Specifications
Item Specification Model DY-3055 Enclosure · body Aluminium alloy frame with electro-galvanised steel panels, static powder coated — corrosion and rust resistant Enclosure · effective space 2400 (L) × 1000 (W) × 1800 (H) mm; volume 4.32 m3 Enclosure · overall dimensions 2400 (L) × 1000 (W) × 2500 (H) mm Enclosure · exhaust High-capacity extraction at the top; runs together with the supply fan after the test to discharge fumes outdoors, and stays closed during the test Enclosure · air supply door Supply door at the rear; opens together with the extraction system after the test and is sealed during the test Enclosure · observation window Tempered glass window at the front, sealable during the test Enclosure · glove ports Sealed glove port below the window so the operator can adjust the burner from outside Temperature sensing · sensor Copper calorimeter with thermocouple — electrolytic copper conductor, 19.14 ± 0.02 mm long Temperature sensing · thermocouple Type K thermocouple in a 0.5 mm stainless steel sheath Temperature sensing · readout Digital thermometer (Taiwan TES) matched to an imported UK type K thermocouple; reads above 1000 °C Temperature sensing · method Portable — the sensor is placed inside the chamber when a temperature check is required Temperature sensing · stopwatch Electronic stopwatch, 0.1 s resolution, for the temperature verification Fixtures · main Test supports and burning burner Fixtures · supports Stainless steel, independent horizontal and vertical types — FT1, FT2 and VW-1. The vertical support and burner lie parallel to the window for easy observation Fixtures · burner UL1581 burner meeting ASTM D 5025-99: 500 W vertical / 225 W horizontal, 0.90 ± 0.03 mm orifice, 1.60 ± 0.05 mm barrel length, orifice 102 mm above the air inlet; 90° horizontal and 20° vertical mounting angles Fixtures · wedge Wedge block lets the burner be mounted, moved and returned precisely to the specified position Fixtures · flame scale Gauge for measuring inner and outer flame in horizontal and vertical tests Fixtures · steel rule 500 mm steel rule with 1 mm graduations Gas control · composition Flow meter, pressure reducing valve and back-pressure manometer Gas control · flow meter 1000 mL/min range Gas control · reducing valve One, adjustable up to 10 lb/in3 gas flow Gas control · back-pressure tube Water column readable to 5 mm or better, using red or green indicating fluid Timing · application Records flame application time automatically once the lit burner reaches position (e.g. 15 s); the operator then swings the wedge away Timing · afterflame Starts automatically when the application timer ends; if the specimen self-extinguishes within the set period a second application follows Timing · afterglow Manually started if the specimen has not extinguished within the afterflame period; failure to extinguish inside the afterglow period is a test failure Timing · cycle counter Automatic count of test cycles with audible alarm (optional) Applicable standards
Standard Scope International reference UL 1581 Reference standard for electrical wires, cables and flexible cords — VW-1 vertical flame test — ASTM D 5025 Laboratory burner for testing small material specimens — UL 13 / UL 444 / UL 1655 Communications and power-limited cables — Dongguan Dongyang Machinery Co., Ltd. — manufacturer of 200+ reliability testing machines. Contact us for quotation: 13790146684 (WhatsApp/WeChat available).